SATEC PM296 µå¶óÀ̺êÀÇ (MODBUS ÇÁ·ÎÅäÄÝ) Àбâ/¾²±â Á¾·ùº° ¸Þ¸ð¸®¿¡ ÀúÀåµÈ ³»¿ë°ú ÀúÀåÀ§Ä¡´Â ´ÙÀ½°ú °°´Ù.
¸Þ¸ð¸® ÀúÀåÀ§Ä¡, Ãâ·Â¹øÁö |
³» ¿ë | ´Ü À§ | ¹ü À§ | modbus address |
¾²±â |
ÀúÀåÀ§Ä¡ + 0 ~ 2 | L1~L3/L12 ~ L31 Àü¾Ð | V | 0 ~ Vmax | 256 ~ 258 | - |
ÀúÀåÀ§Ä¡ + 3 ~ 5 | L1 ~ L3 Àü·ù | A | 0 ~ Imax | 259 ~ 261 | |
ÀúÀåÀ§Ä¡ + 6 ~ 8 | L1 ~ L3 Àü·Â(KW) | KW | -Pmax ~ Pmax | 262 ~ 264 | |
ÀúÀåÀ§Ä¡ + 9 ~ 11 | L1 ~ L3 Kvar | Kvar | 265 ~ 267 | ||
ÀúÀåÀ§Ä¡ +12 ~ 14 | L1 ~ L3 KVA | KVA | 268 ~ 270 | ||
ÀúÀåÀ§Ä¡ +15 ~ 17 | L1 ~ L3 Power Factor | - | -1 ~ 1 | 271 ~ 273 | |
ÀúÀåÀ§Ä¡ +18 | Power Factor Total | 274 | |||
ÀúÀåÀ§Ä¡ +19 | KW Total | KW | -Pmax ~ Pmax | 275 | |
ÀúÀåÀ§Ä¡ +20 | Kvar Total | Kvar | 276 | ||
ÀúÀåÀ§Ä¡ +21 | KVA Total | KVA | 277 | ||
ÀúÀåÀ§Ä¡ +22 | Unbalanced Àü·ù | A | 0 ~ Imax | 278 | |
ÀúÀåÀ§Ä¡ +23 | ÁÖÆļö | HZ | 45 ~ 65 | 279 | |
ÀúÀåÀ§Ä¡ +24 | Sliding window maximum KW demand | KW | -Pmax ~ Pmax | 280 | °¡´É |
ÀúÀåÀ§Ä¡ +25 | Accumulated KW demand | 281 | |||
ÀúÀåÀ§Ä¡ +26 | Sliding window maximum KVA demand | KVA | 282 | ||
ÀúÀåÀ§Ä¡ +27 | Accumulated KVA demand | 283 | |||
ÀúÀåÀ§Ä¡ +28 ~ 30 | Maximum Àü·ù demand L1 ~ L3 | A | 0 ~ Imax | 284 ~ 286 | |
ÀúÀåÀ§Ä¡ +31 ~ 32 | KWh Import Low/High Word | KWh | 0 ~ 9999 | 287 ~ 288 | |
ÀúÀåÀ§Ä¡ +33 | KWh Export Low Word | 289 | |||
ÀúÀåÀ§Ä¡ +34 | KWh Export High Word | 0 ~ 999 | 290 | ||
ÀúÀåÀ§Ä¡ +35 ~ 36 | Kvarh Import Low/High Word | Kvarh | 0 ~ 9999 | 291 ~ 292 | |
ÀúÀåÀ§Ä¡ +37 ~ 38 | Kvarh Export Low/High Word | 293 ~ 294 | |||
ÀúÀåÀ§Ä¡ +39 ~ 41 | L1~L3/L12 ~ L31 THD Àü¾Ð | % | 0 ~ 999.9 | 295 ~ 397 | - |
ÀúÀåÀ§Ä¡ +42 ~ 44 | L1~L3 THD Àü·ù | 398 ~ 300 | |||
ÀúÀåÀ§Ä¡ +45 ~ 46 | KVAh Low/High Word | KVAh | 0 ~ 9999 | 301 ~ 302 | °¡´É |
ÀúÀåÀ§Ä¡ +47 | Sliding window KW demand | KW | -Pmax ~ Pmax | 303 | - |
ÀúÀåÀ§Ä¡ +48 | Sliding window KVA demand | KVA | 304 | ||
ÀúÀåÀ§Ä¡ +49 | Reserved (»ç¿ë¾ÈÇÔ) | - | - | 305 | |
ÀúÀåÀ§Ä¡ +50 ~ 52 | L1 ~ L3 TDD Àü·ù | % | 0 ~ 100 | 306 ~ 308 |
<Ç¥ 1> DATA Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë
¸Þ¸ð¸® ÀúÀåÀ§Ä¡, Ãâ·Â¹øÁö |
³» ¿ë | ´Ü À§ | ¹ü À§ |
modbus address | ¾²±â |
ÀúÀåÀ§Ä¡ + 0 | Wiring mode | - | 0 ~ 6, (0 = 3OP2, 1 = 4LN3, 2 = 3DIR2, 3 = 4LL3, 4 = 3OP3, 5 = 3LN3, 6 = 3LL3) |
2304 | °¡´É |
ÀúÀåÀ§Ä¡ + 1 | PT Ratio | 1.0 ~ 6500.0 |
2305 | ||
ÀúÀåÀ§Ä¡ + 2 | CT Primary Àü·ù | A | 1 ~ 50000 |
2306 | |
ÀúÀåÀ§Ä¡ + 3 | Demand °£°Ý | min | 1, 2, 5, 10, 15, 20, 30, 60, 255 = ¿ÜºÎ Sync |
2307 | |
ÀúÀåÀ§Ä¡ + 4 | Volt/Ampere Demand °£°Ý | sec | 0 ~ 1800 |
2308 | |
ÀúÀåÀ§Ä¡ + 5 | Æò±Õ ¹öÆÛ Å©±â | - | 8, 16, 32 |
2309 | |
ÀúÀåÀ§Ä¡ + 6 | Reset Enable/Disable | 0 = Disable, 1 = Enable |
2310 | ||
ÀúÀåÀ§Ä¡ + 7 | Auxiliary CT Primary Àü·ù | A/mA | 1 ~ 5000 |
2311 | |
ÀúÀåÀ§Ä¡ + 8 | Demand Periods ¼ö | 1 ~ 15 |
2312 | ||
ÀúÀåÀ§Ä¡ + 9 | Thermal Demand Time Constant | Sec | 10 ~ 36000 (0.1 ÃÊ) |
2313 | |
ÀúÀåÀ§Ä¡ + 10 | Waveform Recoder¿¡ ´ëÇÑ Pre-event Cycles ¼ö | - | 1 ~ 8 |
2314 | |
ÀúÀåÀ§Ä¡ + 11 | Nominal ÁÖÆļö | HZ | 50, 60 |
2315 | |
ÀúÀåÀ§Ä¡ + 12 | Max. Demand Load Current | A | 0 ~ 10000 |
2316 | |
ÀúÀåÀ§Ä¡ + 13 | Reserved | - |
|
2317 | |
ÀúÀåÀ§Ä¡ + 14 | DC Volt Offset | 0 ~ 9999 ( ±âº» : 0 ) |
2318 | °¡´É | |
ÀúÀåÀ§Ä¡ + 15 | DC Volt Full Scale | 0 ~ 9999 ( ±âº» : 20100 ¶Ç´Â 300 ) |
2319 | ||
ÀúÀåÀ§Ä¡ + 16 | The Number of Cycles in a Waveform Series | 0 ~ 2560 |
2320 |
<Ç¥ 2> SETUP Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë
¸Þ¸ð¸® ÀúÀåÀ§Ä¡, Ãâ·Â¹øÁö |
³» ¿ë | ¹ü À§ |
modbus address | ¾²±â |
ÀúÀåÀ§Ä¡ + 0 | Instrument reset register | 0 = Àбâ, 65535 = ¾²±â(Warm reset) |
2560 | °¡´É |
ÀúÀåÀ§Ä¡ + 1 | Reserved | Ç×»ó 0 |
2561 | - |
ÀúÀåÀ§Ä¡ + 2 | Relay »óÅ | 0 ~ 5 Bit : Ç×»ó 1, 6 Bit : Relay 2 »óÅÂ, 7 Bit : Relay 1 »óÅÂ, 8 ~ 15 Bit : Ç×»ó 0,
* Relay »óÅÂ 0 = Operated, 1 = Released |
2562 | |
ÀúÀåÀ§Ä¡ + 3 | Reserved | Ç×»ó 0 |
2563 | |
ÀúÀåÀ§Ä¡ + 4 | Status Inputs | 0~3Bit : Status Input 1~4, 4~15Bit : Ç×»ó 0
* Relay »óÅÂ 0 = Open, 1 = Close |
2564 | |
ÀúÀåÀ§Ä¡ + 5 | Firmware version ¹øÈ£ | 0 ~ 65535 |
2565 | |
ÀúÀåÀ§Ä¡ + 6 | Instrument Option 1 | 0 Bit : 120V Option, 1 Bit : 690V Option, 2 ~ 4 Bit : Reserved, 5 Bit : 50% Àü·ù over range option, 6 Bit : Analog Output 0/4 ~ 20mA Option, 7 Bit : Analog Output 0 ~ 1mA Option, 8 Bit : Analog Output -1 ~ +1mA Option, 9 Bit : Relays Option, 10 Bit : Digital Inputs Option, 11 ~ 15 Bit : Reserved |
2566 | |
ÀúÀåÀ§Ä¡ + 7 | Instrument Option 2 | 0 ~ 1 Bit : Number of Relays - 1, 2 ~ 6 Bit : Number of Digital Inputs - 1, 7 ~ 15 Bit : Reserved, |
2567 |
<Ç¥ 3> STATUS Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë
¸Þ¸ð¸® ÀúÀåÀ§Ä¡ | Àбâ/¾²±âAddress | ³» ¿ë | ¹ü À§ |
modbus address |
ÀúÀåÀ§Ä¡ + 0 | 0 | 1¹ø AO allocation register parameter ID | 0 ~ 5659 (SATEC Åë½Å ¸Å´º¾ó ÂüÁ¶) |
3148 |
ÀúÀåÀ§Ä¡ + 1 | 1 | 1¹ø AO zero scale (0/4 mA) | 3149 | |
ÀúÀåÀ§Ä¡ + 2 | 2 | 1¹ø AO full scale (20/1 mA) | 3150 | |
ÀúÀåÀ§Ä¡ + 3 ~ 5 | 3 ~ 5 | 2¹ø AO ÀÇ ID, zero/full scale | 3151 ~ 3153 |
<Ç¥ 4> AO_SET Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë
¸Þ¸ð¸® ÀúÀåÀ§Ä¡ | Àбâ/¾²±âAddress | ³» ¿ë | ¹ü À§ |
modbus address |
ÀúÀåÀ§Ä¡ + 0 | 0 | 1¹ø ACH allocation register parameter ID | 0 ~ 5659 (SATEC Åë½Å ¸Å´º¾ó ÂüÁ¶) |
3196 |
ÀúÀåÀ§Ä¡ + 1 | 1 | 1¹ø ACH zero scale (0/4 mA) | 3197 |
|
ÀúÀåÀ§Ä¡ + 2 | 2 | 1¹ø ACH full scale (20 mA) | 3198 |
|
ÀúÀåÀ§Ä¡ + 3 ~ 5 | 3 ~ 5 | 2¹ø ACH ÀÇ ID, zero/full scale | 3199 ~ 3201 |
|
ÀúÀåÀ§Ä¡ + 6 ~ 8 | 6 ~ 8 | 3¹ø ACH ÀÇ ID, zero/full scale | 3202 ~ 3204 |
|
ÀúÀåÀ§Ä¡ + 9 ~ 38 | 9 ~ 38 | 4 ~ 13¹ø ACH ÀÇ ID, zero/full scale | 3205 ~ 3234 |
|
ÀúÀåÀ§Ä¡ + 39 ~ 41 | 39 ~ 41 | 14¹ø ACH ÀÇ ID, zero/full scale | 3235 ~ 3237 |
<Ç¥ 5> AO_EXP Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë
¸Þ¸ð¸® ÀúÀåÀ§Ä¡ | Àбâ/¾²±âAddress | ³» ¿ë | ¹ü À§ |
modbus ddress |
ÀúÀåÀ§Ä¡ + 0 | 0 | 1¹ø Relay Control »óÅ | 0 = Normal Operation, 1 = Force Operate, 2 = Force Release. |
3244 |
ÀúÀåÀ§Ä¡ + 1 ~ 5 | 1 ~ 5 | 2 ~ 6¹ø Relay Control »óÅ | 3245 ~ 3249 |
<Ç¥ 6> RELAY Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë
¸Þ¸ð¸® ÀúÀåÀ§Ä¡ | Àбâ/¾²±âAddress | ³» ¿ë |
¹ü À§ |
modbus address |
ÀúÀåÀ§Ä¡ + 0 | 0 | Relay 1¹ø Pulsing setpoint Parameter ID |
0 ~ 7 (0 = none, 1 = KWh import, 2 = KWh export, 4 = Kvarh import(inductive), 5 = Kvarh export(capacitive), 6 = Kvarh total, 7 = KVA total) |
2892 |
ÀúÀåÀ§Ä¡ + 1 | 1 | Relay 1¹ø Pulsing setpoint ´ÜÀ§½Ã°£ ´ç Pulse ¼ö |
Energy pulsing = 1 ~ 9999 ±âŸ = 0. |
2893 |
ÀúÀåÀ§Ä¡ + 2 ~ 11 | 2 ~ 11 | Relay 2~5¹ø Parameter ID, ´ÜÀ§½Ã°£ ´ç Pulse ¼ö |
Relay 1¹ø °ú µ¿ÀÏ |
2894 ~2903 |
<Ç¥ 7> PULSE Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë
¸Þ¸ð¸® ÀúÀåÀ§Ä¡ | Àбâ/¾²±âAddress | ³» ¿ë | ¹ü À§ | Modbus address |
ÀúÀåÀ§Ä¡ + 0 | 0 | ÇöÀç½Ã°£ Sec (ÃÊ) | 0 ~ 59 | 4352 |
ÀúÀåÀ§Ä¡ + 1 | 1 | ÇöÀç½Ã°£ Min (ºÐ) | 0 ~ 59 | 4353 |
ÀúÀåÀ§Ä¡ + 2 | 2 | ÇöÀç½Ã°£ Hour (½Ã) | 0 ~ 23 | 4354 |
ÀúÀåÀ§Ä¡ + 3 | 3 | ÇöÀ糯¥ Day (ÀÏ) | 1 ~ 31 | 4355 |
ÀúÀåÀ§Ä¡ + 4 | 4 | ÇöÀ糯¥ Month (¿ù) | 1 ~ 12 | 4356 |
ÀúÀåÀ§Ä¡ + 5 | 5 | ÇöÀ糯¥ Year (³â) | 0 ~ 99 | 4357 |
ÀúÀåÀ§Ä¡ + 6 | 6 | ÇöÀ糯¥ Week (¿äÀÏ) | 1 ~ 7 (1 = Sunday, ¡¦) | 4358 |
<Ç¥ 8> RTC Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë
¸Þ¸ð¸® ÀúÀåÀ§Ä¡ | Àбâ/¾²±â Address | ³» ¿ë |
¹ü À§ |
modbus address |
ÀúÀåÀ§Ä¡ + 0 ~ 119 | 0 ~ 119 | User-Define Register 0 ~ 119 |
(SATEC Power Meter ÀÇ modbus address) |
120 ~ 239 |
<Ç¥ 9> DEFINE Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë
¸Þ¸ð¸® ÀúÀåÀ§Ä¡, Ãâ·Â¹øÁö |
³» ¿ë | ¹ü À§ | modbus address | ¾²±â |
ÀúÀåÀ§Ä¡ + 0 ~ 119 | User-Definable Data 0 ~ 119 | Mapping µÈ(<Ç¥ 9>)
Register ¹øÈ£ (modbus address)¿¡ µû¶ó ¡¦ |
0 ~ 119 | MapµÈ ¹øÁö¿¡ µû¶ó .. |
<Ç¥ 10> MAP Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë
¸Þ¸ð¸® ÀúÀåÀ§Ä¡, Ãâ·Â¹øÁö |
³» ¿ë | ¹ü À§ |
COMM1 address | COMM2 address | ¾²±â |
ÀúÀåÀ§Ä¡ + 0 | Reserved | Ç×»ó 65535 |
2344 | 2352 | - |
ÀúÀåÀ§Ä¡ + 1 | Interface | 1 = RS422, 2 = RS485 |
2345 | 2353 | °¡´É |
ÀúÀåÀ§Ä¡ + 2 | Address | 0 ~ 247 |
2346 | 2354 | |
ÀúÀåÀ§Ä¡ + 3 | Baud rate | 0 = 110, 1 = 300, 2 = 600, 3 = 1200, 4 = 2400, 5 = 4800, 6 = 9600, 7 = 19200 |
2347 | 2355 | |
ÀúÀåÀ§Ä¡ + 4 | Data format | 0 = 7 data bits/even parity, 1 = 8 data bits/no parity, 2 = 8 data bits/even parity |
2348 | 2356 | |
ÀúÀåÀ§Ä¡ + 5 | Incoming Flow Control (COM1 ¸¸) |
0 = No, 1 = XOn/XOff, 2 = CTS |
2349 | 2357 | |
ÀúÀåÀ§Ä¡ +6 | Output Flow Control (COM1 ¸¸) |
0 = RTS not Used, 1 = RTS Permanently Asserted, 2 = RTS During Communication |
2350 | 2358 |
<Ç¥ 11> COMM Àбâ, ¾²±âÀÇ ¸Þ¸ð¸® ÀúÀåÀ§Ä¡¿Í ³»¿ë
* DIRECT – MODBUS Á÷Á¢ ¾îµå·¹½º(Àý´ë¹øÁö : ½ÇÁ¦ MODBUS ¾îµå·¹½º) Àбâ/¾²±â´Â À§ÀÇ <Ç¥ 1> ~ <Ç¥ 19> modbus address Á÷Á¢ ¹øÁö¸¦ ÀÔ·ÂÇÏ¿© Àбâ/¾²±â¸¦ ¼öÇàÇÑ´Ù.
Âü°í) SATEC PM296 Åë½Å µå¶óÀ̺êÀÇ ¾²±â´Â Çѹø¿¡ 2 BYTE( 1 WORD ) µ¥ÀÌÅ͸¦ Power Meter¿¡ Àü¼ÛÇÑ´Ù.
SATEC PM296 Åë½Å µå¶óÀ̺ê´Â À§ÀÇ <Ç¥ 1> ~ <Ç¥ 11> ÀÌ¿Ü¿¡ ¸¹Àº Àбâ/¾²±â ¿µ¿ªÀÌ Á¸ÀçÇϴµ¥,
°¢°¢ÀÇ ¿µ¿ª¿¡ ´ëÇÑ ³»¿ë°ú »ç¿ë¹ýÀº SATEC PM296 Åë½Å ÇÁ·ÎÅäÄÝ »ç¿ë¼³¸í¼¸¦ ÂüÁ¶ÇÏ¿© »ç¿ëÇϽñ⠹ٶø´Ï´Ù.