UFL-20 Flow Meter Series Àº ÀϺ» TOKIMEC INC. ÀÇ À¯·®°è(Flow Meter) Àåºñ¿Í Åë½ÅÀ» À§ÇÑ µå¶óÀ̹öÀÌ´Ù.
Âü°í) UFL-20 Flow Meter Series RS-232C Åë½ÅÀº ÀåºñÀÇ RS-232C »ç¿ëÀÏ ¶§¿¡¸¸ Åë½ÅÀÌ °¡´ÉÇÏ´Ù.
(LCD È¸é ¿À¸¥ÂÊ À§¿¡ RS2 ¶ó´Â ±ÛÀÚ°¡ Ç¥½ÃµÇ¾î ÀÖ¾î¾ß Åë½Å°¡´É)
<±×¸² 1>Àº UFL-20 Flow Meter Series Åë½Å µå¶óÀ̹öÀÇ Åë½Å¼³Á¤ ¿¹ÀÌ´Ù.
<±×¸² 1> UFL-20 Flow Meter Series µå¶óÀ̹öÀÇ Åë½Å ¼³Á¤ ¿¹
<±×¸² 1>ÀÇ DEVICE ¼³Á¤Àº ¿¬°áµÈ ½Ã¸®¾ó Åë½ÅÆ÷Æ® ¹øÈ£(COM1), Åë½Å¼Óµµ(9600), Æи®Æ¼ºñÆ®(2), µ¥ÀÌÅͺñÆ®(8), Á¤ÁöºñÆ®(1) ¼øÀ¸·Î Àåºñ¿¡ ¼³Á¤µÈ °ªÀ» ÀÔ·ÂÇÑ´Ù.
Âü°í) UFL-20 Flow Meter SeriesÀÇ Åë½Å¼Óµµ´Â Àåºñ¿¡¼ ¼³Á¤(1200, 2400, 4800, 9600)ÇÒ ¼ö ÀÖ°í Æи®Æ¼ºñÆ® µîÀº 2, 8, 1 ·Î °íÁ¤µÇ¾î ÀÖ´Ù.
UFL-20 Flow Meter SeriesÀÇ µå¶óÀ̹öÀÇ Àбâ ÀÛ¼º Çü½Ä
UFL-20 Flow Meter Series Åë½Å µå¶óÀ̹öÀÇ Àбâ ÀÛ¼º Çü½ÄÀº ´ÙÀ½°ú °°Àº ÀÎÀÚ ¼øÀ¸·Î ÀÛ¼ºÇÑ´Ù.
1) ÀåºñÀÇ ½ºÅ×ÀÌ¼Ç – »ç¿ë¾ÈÇÔ.
2) ÀÐÀ» µ¥ÀÌÅÍ Á¾·ù – CQQ : Flow Rate or Volume ¼Óµµ Àбâ,
CFI/CBI: FW/BW Integrated Flow Rate Àбâ,
CID : Input MenuÀÇ ¼³Á¤ µ¥ÀÌÅÍ Àбâ,
CCD : Check MenuÀÇ ¼³Á¤ µ¥ÀÌÅÍ Àбâ,
BASICDAT : Reviewing of Basic Data,
CHECK : Self Check,
ERR : Error »óÅ Àбâ,
3) ½ÃÀÛ¹øÁö – »ç¿ë¾ÈÇÔ.
4) Åë½Å ¸Þ¸ð¸® ÀúÀå À§Ä¡ - ÀÐÀº °ªÀÌ ÀúÀåµÉ Åë½Å ¸Þ¸ð¸® ½ÃÀÛ¹øÁö.
5) ÀÐÀ» Å©±â – 1·Î ¼³Á¤. ( ÀÐÀ» µ¥ÀÌÅÍ Á¾·ù¿¡ µû¶ó °íÁ¤, <Ç¥ 1> ÂüÁ¶ )
Àб⠼³Á¤ ¿¹)
READ, 1, CQQ, 0, 0, 1,
READ, 1, CFI, 0, 20, 1,
READ, 1, CBI, 0, 40, 1,
<Ç¥ 1>Àº UFL-20 Flow Meter Series Åë½Å µå¶óÀ̹ö¿¡¼ »ç¿ëÇÏ´Â ÀÐÀ» µ¥ÀÌÅÍ Á¾·ù¿Í ³»¿ëÀÌ´Ù.
ÀÐÀ» µ¥ÀÌÅÍ Á¾·ù | ³»¿ë | ÀÐÀº µ¥ÀÌÅÍ ÀúÀåÀ§Ä¡¿Í ³»¿ë |
Àбâ Á¶°Ç |
CQQ ¶Ç´Â ±âŸ | Flow Rate or Volume ¼Óµµ Àбâ | ÀúÀåÀ§Ä¡ + 0 : Flow Rate °ª, ÀúÀåÀ§Ä¡ + 1 : °íÁ¤µÈ ÀÓÀÇÀÇ °ª, ÀúÀåÀ§Ä¡ + 2 : Flow Rate ´ÜÀ§(0 ~ 14 »çÀÌ °ª, <Ç¥ 2> ÂüÁ¶), ÀúÀåÀ§Ä¡ + 3 : FS(Full Scale Over ÀÏ ¶§ = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 4 : AGC(AGC is Turned On = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 5 : LOW(Ãâ·ÂÀÌ Low Range = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 6 : ROFF(ROFF »óÅ = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 7 : ABN(ABN ±â´É »ç¿ë ½Ã = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 8 : OVER(Upper/Lower Limit Alarm = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 9 : WAGC(AGC Warning »óÅ = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 10 : Reserved(»ç¿ë ¾ÈÇÔ), ÀúÀåÀ§Ä¡ + 11 : LB(¸Þ¸ð¸® ¹èÅ͸®°¡ ¼³Á¤ °ª ÀÌÇÏ = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 12 : ARM(ARM = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 13 : ITG(Integration Mode = 1, ±âŸ = 0) |
Measurement(RUN) »óÅÂÀÏ ¶§ |
CFI/CBI | FW/BW Integrated Flow Rate Àбâ | ÀúÀåÀ§Ä¡ + 0 : FW/BW Integrated value, ÀúÀåÀ§Ä¡ + 1 : Integrated ´ÜÀ§(0 ~ 23 »çÀÌ °ª, <Ç¥ 3> ÂüÁ¶), ÀúÀåÀ§Ä¡ + 2 : FS(Full Scale Over ÀÏ ¶§ = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 3 : AGC(AGC is Turned On = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 4 : LOW(Ãâ·ÂÀÌ Low Range = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 5 : ROFF(ROFF »óÅ = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 6 : ABN(ABN ±â´É »ç¿ë ½Ã = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 7 : OVER(Upper/Lower Limit Alarm = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 8 : WAGC(AGC Warning »óÅ = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 9 : Reserved(»ç¿ë ¾ÈÇÔ), ÀúÀåÀ§Ä¡ + 10 : LB(¸Þ¸ð¸® ¹èÅ͸®°¡ ¼³Á¤ °ª ÀÌÇÏ = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 11 : ARM(ARM = 1, ±âŸ = 0), ÀúÀåÀ§Ä¡ + 12 : ITG(Integration Mode = 1, ±âŸ = 0) |
|
CID | Input MenuÀÇ ¼³Á¤ µ¥ÀÌÅÍ Àбâ | ÀúÀåÀ§Ä¡ + 0 : Function Ç¥½Ã(Flow or Velocity), ÀúÀåÀ§Ä¡ + 1 : Multiplier (E=3 µî), ÀúÀåÀ§Ä¡ + 2 : Flow Rate ÀÏ ¶§ÀÇ ´ÜÀ§, ÀúÀåÀ§Ä¡ + 3 : Density, ÀúÀåÀ§Ä¡ + 4 : A-OUT Type, ÀúÀåÀ§Ä¡ + 5 : FW Max Flow High Range, ÀúÀåÀ§Ä¡ + 6 : FW Max Flow Low Range, ÀúÀåÀ§Ä¡ + 7 : BW Max Flow High Range, ÀúÀåÀ§Ä¡ + 8 : BW Max Flow Low Range, ÀúÀåÀ§Ä¡ + 9 : Classfy(FW/BW or HI/LO), ÀúÀåÀ§Ä¡ + 10 : Auto HI/LO On/Off »óÅÂ, ÀúÀåÀ§Ä¡ + 11 : Limit ON/OFF »óÅÂ, ÀúÀåÀ§Ä¡ + 12 : FW Upper °ª, ÀúÀåÀ§Ä¡ + 13 : FW Lower °ª, ÀúÀåÀ§Ä¡ + 14 : BW Upper °ª, ÀúÀåÀ§Ä¡ + 15 : W Upper °ª, ÀúÀåÀ§Ä¡ + 16 : ROFF ON/OFF »óÅÂ, ÀúÀåÀ§Ä¡ + 17 : FW/BW Ope. ON/OFF »óÅÂ, ÀúÀåÀ§Ä¡ + 18 : FW Zero Shift °ª, ÀúÀåÀ§Ä¡ + 19 : FW Span Corr. °ª, ÀúÀåÀ§Ä¡ + 20 : FW Zero Cut °ª, ÀúÀåÀ§Ä¡ + 21 : BW Zero Shift °ª, ÀúÀåÀ§Ä¡ + 22 : BW Span Corr. °ª, ÀúÀåÀ§Ä¡ + 23 : BW Zero Cut °ª, ÀúÀåÀ§Ä¡ + 24 : ROFF Operation(100%, HOLD, 0%), ÀúÀåÀ§Ä¡ + 25 : Time(0 ~ 120s), ÀúÀåÀ§Ä¡ + 26 : FW Integ. Unit(<Ç¥ 3> ÂüÁ¶), ÀúÀåÀ§Ä¡ + 27 : BW Integ. Unit(<Ç¥ 3> ÂüÁ¶), ÀúÀåÀ§Ä¡ + 28 : Stop Mode(Manual, Timer), ÀúÀåÀ§Ä¡ + 29 : Timer(hhmmss), ÀúÀåÀ§Ä¡ + 30 : BCD Out Interval ½Ã°£(ÃÊ), ÀúÀåÀ§Ä¡ + 31 : Baud Rate(9600, 4800, 2400, 1200), ÀúÀåÀ§Ä¡ + 32 : Remote HI/LO(Contact, RS232C) |
COMMU/HOLD(STOP) »óÅ ÀÏ ¶§
ÀÐÀº °ª ±×´ë·Î STRING ¸Þ¸ð¸®¿¡ º¸°üÇÏ°í = µÚÀÇ ¼ýÀÚ´Â WORD/DWORD/FLOAT ¸Þ¸ð¸®¿¡ ÀúÀå (¼ýÀÚ°¡ ¾Æ´Ï¸é 0 À» ÀúÀå) |
CCD | Check MenuÀÇ ¼³Á¤ µ¥ÀÌÅÍ Àбâ | ÀúÀåÀ§Ä¡ + 0 : A-Out(FINISH, CH1, CH2), ÀúÀåÀ§Ä¡ + 1 ~ 2 : CH1, CH2 setting °ª(%), ÀúÀåÀ§Ä¡ + 3 : Range(FINISH, HI, LO), ÀúÀåÀ§Ä¡ + 4 : Multi Path(FINISH, PATH1 ~ 4), ÀúÀåÀ§Ä¡ + 5 : Gain(Manual, Auto), ÀúÀåÀ§Ä¡ + 6 ~ 9 : Gain 1 ~ 4U Setting °ª, ÀúÀåÀ§Ä¡ + 10 ~ 13 : Gain 1 ~ 4D Setting °ª, ÀúÀåÀ§Ä¡ + 14 : AGC(OFF, ON), ÀúÀåÀ§Ä¡ + 15 ~ 18 : CT0(Design) 1 ~ 4 °ª, ÀúÀåÀ§Ä¡ + 19 ~ 22 : T0(Real) 1 ~ 4 °ª, ÀúÀåÀ§Ä¡ + 23 ~ 26 : Delta 1 ~ 4 °ª, ÀúÀåÀ§Ä¡ + 27 : Reynolds Number °ª, ÀúÀåÀ§Ä¡ + 28 : C0(Real) °ª |
|
BASICDAT | Reviewing of Basic Data | ÀúÀåÀ§Ä¡ + 0 ~ 3 : CT0(Design) 1 ~ 4 °ª, ÀúÀåÀ§Ä¡ + 4 ~ 7 : T0(Real) 1 ~ 4 °ª, ÀúÀåÀ§Ä¡ + 8 ~ 11 : Delta 1 ~ 4 °ª, ÀúÀåÀ§Ä¡ + 12 : Reynolds Number °ª, ÀúÀåÀ§Ä¡ + 13 : C0(Real) °ª |
|
CHECK | CHECK | ÀúÀåÀ§Ä¡ + 0 : ROM Administration Number, ÀúÀåÀ§Ä¡ + 1 : ROM OK or NG, ÀúÀåÀ§Ä¡ + 2 : RAM OK or NG, ÀúÀåÀ§Ä¡ + 3 :,I/O OK or NG, ÀúÀåÀ§Ä¡ + 4 : COUNTER OK or NG, ÀúÀåÀ§Ä¡ + 5 : TX OK or NG, ÀúÀåÀ§Ä¡ + 6 : RX OK or NG, ÀúÀåÀ§Ä¡ + 7 : Counter Á¤»ó = ºóÄ, ÀÌ»ó = ¼ýÀÚ, ÀúÀåÀ§Ä¡ + 8 : Counter Á¤»ó = ºóÄ, ÀÌ»ó = ¼ýÀÚ |
|
ERR | Error »óÅ Àбâ | ÀúÀåÀ§Ä¡ + 0 : wCOM Ç¥½Ã, ÀúÀåÀ§Ä¡ + 1 : COMMAND, ÀúÀåÀ§Ä¡ + 2 : DATA, ÀúÀåÀ§Ä¡ + 3 : ITG, ÀúÀåÀ§Ä¡ + 4 : KEY |
Measurement(RUN), COMMU/HOLD(STOP) »óÅ ÀÏ ¶§(Ç×»ó) |
<Ç¥ 1> UFL-20 Flow Meter Series Åë½Å µå¶óÀ̹ö¿¡¼ »ç¿ëÇÏ´Â ÀÐÀ» µ¥ÀÌÅÍ Á¾·ù¿Í ³»¿ë
´Ü À§ |
ÀúÀå °ª |
M3/D |
0 |
M3/h |
1 |
M3/m |
2 |
m3/s |
3 |
L/h |
4 |
L/m |
5 |
L/s |
6 |
t/D |
7 |
t/h |
8 |
t/m |
9 |
t/s |
10 |
kg/h |
11 |
kg/m |
12 |
kg/s |
13 |
±âŸ |
14 |
<Ç¥ 2> UFL-20 Flow Meter Series Åë½Å µå¶óÀ̹öÀÇ Flow Rate ´ÜÀ§¿Í ÀúÀå °ª
´Ü À§ |
ÀúÀå °ª |
NONE |
0 |
x10000m3 |
1 |
x1000m3 |
2 |
x100m3 |
3 |
x10m3 |
4 |
x1m3 |
5 |
x100L |
6 |
x10L |
7 |
x1L |
8 |
x100mL |
9 |
x10mL |
10 |
x100kt |
11 |
x10kt |
12 |
x1kt |
13 |
x100t |
14 |
x10t |
15 |
x1t |
16 |
x100kg |
17 |
x10kg |
18 |
x1kg |
19 |
x100g |
20 |
x10g |
21 |
x1g |
22 |
±âŸ |
23 |
<Ç¥ 3> UFL-20 Flow Meter Series Åë½Å µå¶óÀ̹öÀÇ Integrated ´ÜÀ§¿Í ÀúÀå °ª
ÁÖÀÇ) UFL-20 Flow Meter Series µå¶óÀ̹öÀÇ ÀÐÀº °ªÀº WORD/FLOAT/DWORD/STRING ¸Þ¸ð¸®¿¡ µ¿ÀÏÇÑ ÀúÀåÀ§Ä¡¿¡ ÀúÀåµÇ°í ÀúÀå °ªÀº ¸Þ¸ð¸® Çü½Ä¿¡ µû¶ó ´Ù¸£´Ù.
<±×¸² 1> ÇÁ·ÎÅäÄÝ ¿É¼ÇºÎÀÇ ¾ÆÀÌÄÜÀ» Ŭ¸¯Çϸé <±×¸² 2>ÀÇ ´ëÈ»óÀÚ°¡ ³ªÅ¸³ª´Âµ¥ ¿©±â¼µµ Àбâ Çü½ÄÀ» ÀÛ¼ºÇÒ ¼ö ÀÖ´Ù.
<±×¸² 2> UFL-20 Flow Meter Series Åë½Å µå¶óÀ̹öÀÇ Àб⠼³Á¤ ´ëÈ»óÀÚ
<±×¸² 2>ÀÇ , , ¹öÅÏ°ú ¸®½ºÆ® ¹Ú½º¸¦ ÀÌ¿ëÇÏ¿© Àбâ Çü½ÄÀ» ÀÛ¼ºÇÑ´Ù.
<±×¸² 3>´Â <±×¸² 2>ÀÇ ´ëÈ»óÀÚ¿¡¼ Àбâ Çü½ÄÀ» Ãß°¡ ¶Ç´Â ÆíÁýÇÒ ¶§ ³ªÅ¸³ª´Â ´ëÈ»óÀÚÀÌ´Ù.
<±×¸² 3> UFL-20 Flow Meter Series Åë½Å µå¶óÀ̹öÀÇ Àб⠼³Á¤ READ Ãß°¡/ÆíÁý ´ëÈ»óÀÚÀÇ ¿¹
¾²±â ¼³Á¤À¸·Î UFL-20 Flow Meter Series Àåºñ¸¦ ¼³Á¤ÇÒ ¼ö ÀÖ´Ù.
µðÁöÅÐ ¾²±â
µðÁöÅÐ ¾²±â´Â ¾Æ³¯·Î±× ¾²±â¿Í µ¿ÀÏÇÑ ¹æ¹ýÀ¸·Î ¼³Á¤ÇÏ°í Ãâ·Â °ª¸¸ ´Ù¸£´Ù.
¾Æ³¯·Î±× ¾²±â
¾Æ³¯·Î±× ¾²±â¸¦ À§ÇÑ ¾Æ³¯·Î±× Ãâ·Â ÅÂ±× ¼³Á¤ ½Ã ÇÊ¿äÇÑ ¿ä¼Ò
1) Port ¿¬°áµÈ Åë½ÅÆ÷Æ® ¹øÈ£. (COM ¹øÈ£°¡ ¾Æ´Ô)
2) Station »ç¿ë¾ÈÇÔ.
3) Address ¾²±â ¸í·ÉÀÏ ¶§ – 0 = ¸í·É¾î ÀÔ·Â, 1, ±âŸ = ¸í·É¾î¿Í ¸í·ÉÀÎÀÚ ¸ðµÎ¸¦ ÀÔ·Â,
Àб⠸í·ÉÀÏ ¶§ – »ç¿ë¾ÈÇÔ.
4) Extra1 ¾²±â/Àб⠸í·É¾î,
BCDINTRVL : Setting of Renewal Cycle of BCD Output,
REMOTEHL : Selection of Range Changing Method,
AOUTFNSH : Finishing of A-Out Check,
INTUNIT : Selection of Integrated Unit,
ISTPMOD : Selection of Stopping Method of Integration,
DENSITY : Setting of Fluid Density,
ROFFALM : On/Off Selection of ROFF Alarm Output,
FWBWOPE : On/Off Selecting of Forward/Backward Change Confirmation,
ROFFOPE : Selecting of R-OFF Operation,
FAOTYP : Selection of Analog Output Type During Flow Meter,
VAOTYP : Selection of Analog Output Type During Velocity Meter,
LMTALM : On/Off Selection of High/Low Limit Alarm,
LMTVAL : Setting of High/Low Limit Alarm Value,
SMOOTH : Setting of Dumping Time for Smoothing Filter,
Z_SFT : Setting of Zero Shift,
Z_CUT : Setting of Zero Cut,
RANGE : Setting of Range Check,
MULTI : Setting of Measuring Path Fixing,
FUNC : Switching to Flow Meter or Velocity Meter,
UNIT : Selection of Flow Rate Unit,
SPAN : Setting of Span Adjustment,
AOUT : Setting of A-OUT Check,
GAIN : Setting of Manual Gain,
STP : Stopping Measurement,
RUN : Starting Measurement,
ISP : Stopping Integration,
IST : Starting Integration,
RGH : Changing Range to High,
RGL : Changing Range to Low,
AGC : On/Off Selection of AGC,
AGA : Starting Automatic Gain Adjustment,
CQQ, CFI/CBI, CID, CCD, BASICDAT, CHECK , ERR : Àб⠸í·É(<Ç¥ 1>ÂüÁ¶),
5) Extra2 ¾²±â Á¾·ù¿¡ µû¶ó ¼³Á¤ °ª µîÀ» ÀÔ·Â. (< Ç¥ 4> ÂüÁ¶)
<Ç¥ 2>´Â UFL-20 Flow Meter Series Åë½Å µå¶óÀ̹ö¿¡¼ »ç¿ëÇÏ´Â Ãâ·Â Á¾·ù¿Í Ãâ·ÂÀÎÀÚ µî¿¡ ´ëÇÑ ¼³¸íÀÌ°í <Ç¥ 3>Àº ´Ù¿î·Îµå µ¥ÀÌÅÍ ÀԷ¹æ¹ýÀÌ´Ù.
¸í·É¾î Á¾·ù(Extra1) | Address | Extra2 |
Ãâ·Â/´Ù¿î·Îµå µ¥ÀÌÅÍ |
³»¿ë |
Á¶°Ç |
BCDINTRVL | 0 = ¸í·É¾î ÀÔ·Â, 1, ±âŸ = ¸í·É¾î¿Í ¸í·ÉÀÎÀÚ ¸ðµÎ¸¦ ÀÔ·Â |
»ç¿ë¾ÈÇÔ |
0 ~ 99 |
Setting of Renewal Cycle of BCD Output |
COMMU/HOLD(STOP) »óÅ ÀÏ ¶§ |
REMOTEHL |
|
0 = Contact, 1 = RS232C |
Selection of Range Changing Method |
||
AOUTFNSH |
|
»ç¿ë¾ÈÇÔ |
Finishing of A-Out Check |
||
INTUNIT | 0 ~ 22 »çÀÌÀÇ FW Integration ´ÜÀ§ °ª(<Ç¥ 3> ÂüÁ¶) |
0 ~ 22 »çÀÌÀÇ BW Integration ´ÜÀ§ °ª(<Ç¥ 3> ÂüÁ¶) |
Selection of Integrated Unit |
||
ISTPMOD | 0 = Manual, 1 = Timer |
Extra2 = 1 ÀÏ ¶§, Hhmmss ¼³Á¤ °ª (hh = 0 ~ 99 ½Ã°£, mm/ss = 0 ~ 59 ºÐ/ÃÊ) |
Selection of Stopping Method of Integration |
||
DENSITY | »ç¿ë¾ÈÇÔ |
0.1 ~ 9.0 ÀÇ Density ¼³Á¤ °ª |
Setting of Fluid Density |
||
ROFFALM | 0 = OFF, 1 = ON |
On/Off Selection of ROFF Alarm Output |
|||
FWBWOPE | 0 = OFF, 1 = ON |
On/Off Selecting of Forward/Backward Change Confirmation |
|||
ROFFOPE | 0 = Z(0 %), 1 = H(Hold), 2 = F(100 %) |
Selecting of R-OFF Operation |
|||
FAOTYP | 0 ~ 999 »çÀÌÀÇ ÆÄÀϹøÈ£, ÀÛ¾÷µð·ºÅ丮\SCAN\ data%03d_%03d.ini ¸í·ÉÀÔ·Â (¾Õ %03d : PORT ¹øÈ£, µÚ %03d : Extra2 °ª) |
»ç¿ë¾ÈÇÔ
7°³ÀÇ ¼³Á¤ ÀÎÀÚ´Â <Ç¥ 6>¸¦ ÂüÁ¶ÇÏ¿© ÀÔ·Â |
Selection of Analog Output Type During Flow Meter |
||
VAOTYP | Selection of Analog Output Type During Velocity Meter |
||||
LMTALM | »ç¿ë¾ÈÇÔ |
0 = OFF, 1 = ON |
On/Off Selection of High/Low Limit Alarm |
||
LMTVAL | 0 ~ 999 »çÀÌÀÇ ÆÄÀϹøÈ£, ÀÛ¾÷µð·ºÅ丮\SCAN\ data%03d_%03d.ini ¸í·ÉÀÔ·Â (¾Õ %03d : PORT ¹øÈ£, µÚ %03d : Extra2 °ª) |
»ç¿ë¾ÈÇÔ
4°³ÀÇ ¼³Á¤ ÀÎÀÚ´Â FW Upper/Lower(0.000 ~ 9999.0), BW Upper/Lower(0.000 ~ -9999.0) ¼øÀ¸·Î ÀÔ·Â |
Setting of High/Low Limit Alarm Value |
||
SMOOTH | »ç¿ë¾ÈÇÔ |
0 ~ 120 (ÃÊ) |
Setting of Dumping Time for Smoothing Filter |
||
Z_SFT | 0 ~ 999 »çÀÌÀÇ ÆÄÀϹøÈ£, ÀÛ¾÷µð·ºÅ丮\SCAN\ data%03d_%03d.ini ¸í·ÉÀÔ·Â (¾Õ %03d : PORT ¹øÈ£, µÚ %03d : Extra2 °ª) |
»ç¿ë¾ÈÇÔ 2°³ÀÇ ¼³Á¤ ÀÎÀÚ´Â FW, BW Zero Shift °ª(-9999.0 ~ 9999.0)À» ÀÔ·Â |
Setting of Zero Shift |
||
Z_CUT | »ç¿ë¾ÈÇÔ 2°³ÀÇ ¼³Á¤ ÀÎÀÚ´Â FW, BW Zero Shift °ª(-9999.0 ~ 9999.0)À» ÀÔ·Â |
Setting of Zero Cut |
|||
SPAN | »ç¿ë¾ÈÇÔ 2°³ÀÇ ¼³Á¤ ÀÎÀÚ´Â FW(0.000 ~ 9999.0), BW(0.000 ~ -9999.0) Zero Shift °ªÀ» ÀÔ·Â |
Setting of Span Adjustment |
|||
GAIN | »ç¿ë¾ÈÇÔ 3°³ÀÇ ¼³Á¤ ÀÎÀÚ´Â 1 ~ 4 ÀÇ Ã¤³Î ¹øÈ£, U(Up Gain) ¶Ç´Â D(Down Gain), Gain °ª(0 ~ 204)À» ÀÔ·Â |
Setting of Manual Gain |
|||
RANGE | »ç¿ë¾ÈÇÔ |
0 = FINISH, 1 = HI, 2 = LO |
Setting of Range Check |
||
MULTI | 0 = FINISH, 1 = CH1, 2 = CH2, 3 = CH3, 4 = CH4 |
Setting of Measuring Path Fixing |
|||
FUNC | 0 = FLOW, 1 = VELO |
Switching to Flow Meter or Velocity Meter |
|||
UNIT | 0 = E-6, 1 = E-3, 2 = 1, 3 = E+3, 4 = E=6, 5 = E=6 |
0 ~ 13 »çÀÌ °ªÀ» ÀÔ·Â (ÀÔ·Â °ª º° ´ÜÀ§´Â <Ç¥ 2>ÂüÁ¶) |
Selection of Flow Rate Unit |
||
AOUT | 0 = CH1, 1 = CH2 |
-100.0 ~ 100.0 (%) |
Setting of A-OUT Check |
||
STP | »ç¿ë¾ÈÇÔ |
»ç¿ë¾ÈÇÔ (Ãâ·Â °ª ¾øÀÌ ¼³Á¤) |
Stopping Measurement |
Measurement(RUN) »óÅÂÀÏ ¶§ |
|
RUN | Starting Measurement |
||||
ISP | Stopping Integration |
Measurement(RUN), COMMU/HOLD(STOP) »óÅ ÀÏ ¶§(Ç×»ó) |
|||
IST | Starting Integration |
||||
RGH | Changing Range to High |
Measurement(RUN) INTEG. STOP »óÅÂÀÏ ¶§ |
|||
RGL | Changing Range to Low |
||||
AGC | 0 = OFF, 1 = ON |
On/Off Selection of AGC |
COMMU/HOLD(STOP) »óÅ ÀÏ ¶§ |
||
AGA | 1 ~ 4 CH ¹øÈ£ ÀÔ·Â |
Starting Automatic Gain Adjustment |
|||
CQQ, CFI/CBI, CID, CCD, BASICDAT, CHECK , ERR | »ç¿ë¾ÈÇÔ | ÀÐÀº °ªÀ» ÀúÀåÇÒ ¸Þ¸ð¸® ½ÃÀÛ¹øÁö |
»ç¿ë¾ÈÇÔ |
Àб⠸í·É |
<Ç¥ 1>ÂüÁ¶ |
<Ç¥ 4> UFL-20 Flow Meter Series Åë½Å µå¶óÀ̹ö¿¡¼ »ç¿ëÇÏ´Â Ãâ·Â Á¾·ù¿Í Ãâ·ÂÀÎÀÚ µî¿¡ ´ëÇÑ ¼³¸í
ÆÄÀÏ À̸§ |
ÀÛ¾÷µð·ºÅ丮\SCAN\ data%03d_%03d.ini ¸í·ÉÀÔ·Â (¾Õ %03d : PORT ¹øÈ£, µÚ %03d : Extra2 °ª) |
ÀÛ¼º ¹æ¹ý |
ÄÞ¸¶( , )·Î ±¸ºÐµÈ ¼ýÀÚ¸¦ ÇÑ ÁÙ¿¡ ÀÔ·Â |
¼ýÀÚ/¹®ÀÚ ÀԷ¹æ¹ý |
ÇÑ ÁÙ¿¡ 10Áø¼ö ¼ýÀÚ ¶Ç´Â ¹®ÀÚ µîÀ» ÀûÀýÇÏ°Ô ÀÔ·Â |
<Ç¥ 5> UFL-20 Flow Meter Series Åë½Å µå¶óÀ̹ö¿¡ »ç¿ëµÇ´Â ¼³Á¤ÀÎÀÚ µ¥ÀÌÅÍ ÀԷ¹æ¹ý
¼³Á¤ÀÎÀÚ |
³»¿ë |
¹üÀ§ ¶Ç´Â ¹®ÀÚ |
ù ¹ø° |
Type |
1:+:SNGL - One System, Unidirectional, Single range output, 1:+/-:SNGL - One System, Bi-directional, Single range output, 1:+:DBL - One System, Unidirectional, Double range output, 1:+/-:DBL - One System, Bi-directional, Double range output, 2:+/-:SNGL - Two System, Bi-directional, Single range output, 2:+:DBL - Two System, Unidirectional, Double range output, 2:+/-:DBL - Two System, Bi-directional, Double range output, SPECIAL - Special output. |
µÎ ¹ø° |
FW
|
0.00 ~ 99.00 |
¼¼ ¹ø° |
FW
|
0.00 ~ 99.00 |
³× ¹ø° |
BW
|
0.00 ~ -99.00 |
´Ù¼¸ ¹ø° |
BW
|
0.00 ~ -99.00 |
¿©¼¸ ¹ø° |
Setting Classfy |
F/B - Setting Classfy to FW/BW, H/L - Setting Classfy to HI/LO. |
ÀÏ°ö ¹ø° |
Double Range Auto ¸ðµå ¼³Á¤ |
ON - Automatic range, OFF - Manual range. |
<Ç¥ 6> UFL-20 Flow Meter Series Åë½Å µå¶óÀ̹ö¿¡ »ç¿ëµÇ´Â FAOTYP, VAOTYP ¸í·ÉÀÇ ¼³Á¤ÀÎÀÚ ÀԷ¼ø¼¿Í ³»¿ë
¼³Á¤ ¿¹1)
PORT : 0 STATION : 0 ADDRESS : 0000 EXTRA1 : STP EXTRA2 : 0 À¸·Î ¼³Á¤ÇÏ°í ¾Æ³¯·Î±× Ãâ·ÂÀ» Çϸé 0 ¹ø Æ÷Æ®¿¡ ¿¬°áµÈ UFL-20 Flow Meter Series Àåºñ¸¦ Á¤Áö(Measurement ¸ðµåÀÏ °æ¿ì) ½Ãų ¼ö ÀÖ´Ù.
¼³Á¤ ¿¹2)
PORT : 0 STATION : 0 ADDRESS : 0000 EXTRA1 : RUN EXTRA2 : 0 À¸·Î ¼³Á¤ÇÏ°í ¾Æ³¯·Î±× Ãâ·ÂÀ» Çϸé 0 ¹ø Æ÷Æ®¿¡ ¿¬°áµÈ UFL-20 Flow Meter Series Àåºñ¸¦ Measurement ¸ðµå·Î º¯°æ(COMMU/HOLD ÀÏ ¶§)ÇÒ ¼ö ÀÖ´Ù.
¼³Á¤ ¿¹3)
PORT : 0 STATION : 0 ADDRESS : 0000 EXTRA1 : FUNC EXTRA2 : 0 À¸·Î ¼³Á¤ÇÏ°í 1ÀÇ ¾Æ³¯·Î±× °ªÀ» Ãâ·ÂÇϸé 0 ¹ø Æ÷Æ®¿¡ ¿¬°áµÈ UFL-20 Flow Meter Series Àåºñ¸¦ Velocity ¸ðµå·Î º¯°æ(COMMU/HOLD ÀÏ ¶§)ÇÒ ¼ö ÀÖ´Ù.
¼³Á¤ ¿¹4)
PORT : 0 STATION : 0 ADDRESS : 0000 EXTRA1 : UNIT EXTRA2 : 3 À¸·Î ¼³Á¤ÇÏ°í 1ÀÇ ¾Æ³¯·Î±× °ªÀ» Ãâ·ÂÇϸé 0 ¹ø Æ÷Æ®¿¡ ¿¬°áµÈ UFL-20 Flow Meter Series ÀåºñÀÇ ´ÜÀ§¸¦ M3/h, E+3 À¸·Î º¯°æ(COMMU/HOLD ÀÏ ¶§)ÇÒ ¼ö ÀÖ´Ù.
¼³Á¤ ¿¹5)
PORT : 0 STATION : 0 ADDRESS : 0000 EXTRA1 : FAOTYP EXTRA2 : 2 À¸·Î ¼³Á¤ÇÏ°í ¾Æ³¯·Î±× Ãâ·ÂÀ» Çϸé 0 ¹ø Æ÷Æ®¿¡ ¿¬°áµÈ UFL-20 Flow Meter Series ÀåºñÀÇ Selection of Analog Output Type During Flow Meter °ªÀ» ¼³Á¤(COMMU/HOLD ÀÏ ¶§)ÇÒ ¼ö ÀÖ´Ù. ( ´Ü ¼³Á¤ÀÎÀÚ 7°³ µ¥ÀÌÅÍ´Â ¡®ÀÛ¾÷µð·ºÅ丮\SCAN\data000_002.ini¡¯ ÆÄÀÏ¿¡ ÀԷµǾî ÀÖ¾î¾ß ÇÑ´Ù. )
Âü°í) ¼³Á¤ÀÎÀÚ 7°³ µ¥ÀÌÅÍ ÀÔ·Â ¿¹) 1:+:SNGL,50.0,0.0,0.0,0.0,F/B,OFF, (One System-Unidirectional-Single range output, FW High/Low Range 50.0, 0.0, BW High/Low Range ¡¦,)
UFL-20 Flow Meter Series ÀåºñÀÇ RS-232C Åë½ÅÄÉÀÌºí ¹× ±âº»Àü¿øÀº ´ÙÀ½°ú °°ÀÌ ¿¬°áÇÑ´Ù.
Åë½ÅÄÉÀÌºí ¿¬°á
UFL-20 Flow Meter Series ÀåºñÀÇ RS232C ´ÜÀÚ(<±×¸² 4> ÂüÁ¶)¿¡ RS-232C Åë½ÅÄÉÀ̺íÀ» ¿¬°áÇÑ´Ù.
<±×¸² 4>´Â UFL-20 Flow Meter Series ÀåºñÀÇ ¸ð½ÀÀÌ´Ù.
<±×¸² 4> UFL-20 Flow Meter Series ÀåºñÀÇ ¸ð½À
±âº»Àü¿ø ¿¬°á
<±×¸² 4>¿Í °°Àº UFL-20 Flow Meter Series ÀåºñÀÇ L, N ´ÜÀÚ¿¡ 220 V AC µîÀÇ ±âº»Àü¿øÀ» ¿¬°áÇÑ´Ù.
1. Àü¿ø ½ºÀ§Ä¡ ON
2. MENU Key ´©¸§
3. ¡°5693¡±+ ENT (DISPLAY â »ó´Ü¿¡ S1ÀÌ »ý±â´ÂÁö È®ÀÎ)
4. ¸Þ´º 1¹ø INPUT + ENT
5. ¸Þ´º 1¹ø MEAS.DATA + ENT
6. ¼ýÀÚ ¡°0¡±À» Çѹø ´©¸§
7. ¸Þ´º 7¹ø OTHER DATA + ENT
8. ¡°1126¡± + ENT
9. ¸Þ´º 3¹ø OPTION + ENT
10. ¸Þ´º 2¹ø RS232C + ENT
11. OFF -> ON (¹æÇâ KEY ¡è ´©¸§ ) + ENT
12. EXIT Key¸¦ ´©¸§ (óÀ½ ȸéÀ¸·Î °¨)
13. MENU Key ´©¸§
14. ¸Þ´º 1¹ø INPUT + ENT
15. ¸Þ´º 3¹ø RS232C + ENT
16. ¸Þ´º 1¹ø BAUD RATE + ENT
17. ¹æÇâ Key ¡è, ¡é ·Î Åë½Å ¼Óµµ ÁöÁ¤(9600) + ENT
18. ¸Þ´º 2¹ø REMOTE HI/LO + ENT
19. ¸Þ´º 2¹ø RS232C ¼±Åà + ENT
20. EXIT Key¸¦ ´©¸§ (óÀ½ ȸéÀ¸·Î °¨)