KACO Pawador Inverter communication driver is the driver to communicate with inverter controller of KACO Geratetechnic GmbH in Germany.
<Figure 1> is read setting example of KACO Pawador Inverter communication driver.
<Figure 1> Read setting example of KACO Pawador Inverter communication driver |
Device part of <Figure 1> input Com Port(COM1), Baud Rate(9600), Parity Bit(0), Data Bit(8), Stop Bit(1) respectively, according to controller.
KACO Pawador Inverter communication driver read schedule
Read schedule setting parameters are as follows:
1) Station – 1 ~ 32 controller station number.
2) Read data type – 0 : 3000xi model = read of 3000xi identify, other model = read of inverter data,
1 ~ 3 : part 1 ~ 3 inverter data for 3000xi model.
3) Controller model – 0 : 3000xi model, 1 : 2500xi ~ 5000xi, 1501xi ~ 3501xi, etc.
4) Save start address for Communication Server – Saving start address of Communication Server.
5) Read Size – Fixed according to read data type.
Read schedule example)
READ, 1, 0, 0, 0, 1,
READ, 2, 0, 0, 10, 1,
<Table 1> is data saving address and contents for KACO Pawador Inverter communication driver.
<Table 2> is data value and contents for status data.
Data saving address | Contents | Units | Remarks |
Start addr + 0 | 0 ~ 3 read data type | - | |
Start addr + 1 | status data | - | refer to <Table 2> |
Start addr + 2 | generator voltage | V | |
Start addr + 3 | generator current | A | |
Start addr + 4 | generator power | W | |
Start addr + 5 | grid voltage | V | |
Start addr + 6 | grid current, delivered current | A | |
Start addr + 7 | grid-feeding power | W | |
Start addr + 8 | temperature of controller | ¡É | |
Start addr + 9 | Yield Today | Wh | |
Start addr + 10 | inverter type, mnemonic | save also at STRING memory | |
Start addr + 11 | total Yield | KWh | |
<Table 1> Data saving address and contents for KACO Pawador Inverter communication driver |
Status value |
Contents |
0 |
Inverter has just switched on |
1 |
Waiting for start |
2 |
Waiting for shut down |
3 |
Constant voltage regulator |
4 |
MPP-tracker, permanent search/tracking movement |
5 |
MPP-tracker, without search/tracking movement |
6 |
Wait mode before grid feeding, Test grid and solar voltage |
7 |
Wait mode before self test, Test grid and solar voltage |
8 |
Self-test relays |
10 |
Over temperature shut-off |
11 |
Power limitation |
12 |
Overload shut-off |
13 |
Over voltage shut-off |
14 |
Grid failure(1 phase monitoring) |
15 |
Transition to night shut-down |
18 |
RCD shut-down |
19 |
Insufficient insulation resistance |
30 |
Measuring error |
31 |
RCD module error |
32 |
Self-test error |
33 |
DC grid-feeding error |
34 |
Communication error |
<Table 2> Data value and contents for status data |
KACO Pawador Inverter communication driver store the same data in WORD, DWORD, FLOAT memory, but the data format are different.
If you click the icon in protocol option part at <Figure 1>, you can see the dialogue box such as <Figure 2>. you can also set read schedule by using this part.
<Figure 2> Example of KACO Pawador Inverter communication driver¡¯s Option dialog box |
You can set read schedule by using , , button and listbox of <Figure 2>.
<Figure 3> Example of KACO Pawador Inverter communication driver¡¯s read schedule Add/Edit dialog box |
When you click Add button or Edit button in dialogue box of <Figure 2>, dialogue box of <Figure 3> is shown.
KACO Pawador Inverter communication driver don't support 'Writing settings'.
<Figure 4> is apperance of KACO Pawador Inverter controller.
<Figure 4> Apperance of KACO Pawador Inverter controller |