BETA LASERMIKE Diameter Communication Driver is the driver to communicate with Accuscan LD1010/25/40 outer diameter measurement.
<Figure 1> is read setting example of BETA LASERMIKE Diameter communication driver.
<Figure 1> Read setting example of BETA LASERMIKE Diameter communication driver |
Device part of <Figure 1> input Com Port(COM1), Baud Rate(9600), Parity Bit(0), Data Bit(7), Stop Bit(2) respectively.
BETA LASERMIKE Diameter communication driver¡¯s read schedule
Read schedule setting parameters are as follows:
1) STATION – Don't care.
2) Read command – Command = A, B, C, D, E, F, G, J, K, L, M, N, O, P, Q, S, V, (A), (B), (C), (E), (F), (J), (K), (L), (M), (Z), {C}, {F}, {K}, {L}, {M}, {N}, {O}, {P}, |A|, |B|, |C|, |D|. |E|, |F|, |G|, |J| ¿Í CONT(continuous mode data read).
(Refer to BETA LASERMIKE Diameter Instruction Handbook )
3) Read start address –Don't care.
4) Save start address for Communication Server – Saving start address of Communication Server.
5) Read Size – CONT read command = 7 or 9,
other read command = Fix to 1.
Read schedule example)
READ, 0, A, 0, 0, 1,
READ, 0, B, 0, 1, 1,
READ, 0, C, 0, 2, 1,
READ, 0, D, 0, 3, 1,
READ, 0, E, 0, 4, 1,
READ, 0, F, 0, 5, 1,
READ, 0, G, 0, 6, 1,
You can send data to BETA LASERMIKE Diameter by using write commands.
Bit Write
Bit write setting parameters are as follows:
1) PORT Port no. (0 ~ 255)
2) STATION Don't care..
3) ADDRESS Read command - save start 'WORD' address of readed data.(10 degit)
Write command - Don't care.
4) EXTRA1 Read/Write command.
Read command - A, B, C, D, E, F, G, J, K, L, M, N, O, P, Q, S, V, (A), (B), (C), (E), (F), (J), (K), (L), (M), (Z), {C}, {F}, {K}, {L}, {M}, {N}, {O}, {P}, |A|, |B|, |C|, |D|. |E|, |F|, |G|, |J| ¿Í CONT.
Write command – H, >, !, I, k, m, n, o, p, q, s, (a), (e), (f), (j), (k), (l), (m), (z), |a|, |b|, |c|, |d|, |e|, |f|, |g|, |j|.
H, >, ! - Enable Continuous mode, (When Continuous Mode, receive data continuous data from BATA LASERMIKE Diameter. (use 'CONT' read command) )
I - Disable Continuous mode.
(Refer to BETA LASERMIKE Diameter Instruction Handbook )
5) EXTRA2 Don't care.
Word Write
Word write and bit write have the same setting parameters except output value.