BETA LASERMIKE Diameter Communication Driver

 

BETA LASERMIKE Diameter Communication Driver is the driver to communicate with Accuscan LD1010/25/40 outer diameter measurement.

 

1. Read settings

 

<Figure 1> is read setting example of BETA LASERMIKE Diameter communication driver.

<Figure 1>  Read setting example of BETA LASERMIKE Diameter communication driver

Device part of  <Figure 1> input Com Port(COM1), Baud Rate(9600), Parity Bit(0), Data Bit(7), Stop Bit(2) respectively.

 

 

BETA LASERMIKE Diameter communication driver¡¯s read schedule

Read schedule setting parameters are as follows:

1) STATION – Don't care.

2) Read command – Command = A, B, C, D, E, F, G, J, K, L, M, N, O, P, Q, S, V, (A), (B), (C), (E), (F), (J), (K), (L), (M), (Z), {C}, {F}, {K}, {L}, {M}, {N}, {O}, {P}, |A|, |B|, |C|, |D|. |E|, |F|, |G|, |J| ¿Í CONT(continuous mode data read).

                                      (Refer to BETA LASERMIKE Diameter Instruction Handbook )

3) Read start address –Don't care.

4) Save start address for Communication Server – Saving start address of Communication Server.

5) Read Size – CONT read command = 7 or 9,

                            other read command = Fix to 1.

 

Read schedule example)

READ,    0,     A,     0,    0,   1,

READ,    0,     B,     0,    1,   1,

READ,    0,     C,     0,    2,   1,

READ,    0,     D,     0,    3,   1,

READ,    0,     E,     0,    4,   1,

READ,    0,     F,     0,    5,   1,

READ,    0,     G,     0,    6,   1,

 

 

2. Writing settings

You can send data to BETA LASERMIKE Diameter by using write commands.

 

Bit Write

Bit write setting parameters are as follows:

1)  PORT               Port no. (0 ~ 255)

2)  STATION         Don't care..

3) ADDRESS        Read command - save start 'WORD' address of readed data.(10 degit)

                   Write command - Don't care.

4) EXTRA1            Read/Write command.

Read command - A, B, C, D, E, F, G, J, K, L, M, N, O, P, Q, S, V, (A), (B), (C), (E), (F), (J), (K), (L), (M), (Z), {C}, {F}, {K}, {L}, {M}, {N}, {O}, {P}, |A|, |B|, |C|, |D|. |E|, |F|, |G|, |J| ¿Í CONT.

Write command – H, >, !, I, k, m, n, o, p, q, s, (a), (e), (f), (j), (k), (l), (m), (z), |a|, |b|, |c|, |d|, |e|, |f|, |g|, |j|.

H, >, ! - Enable Continuous mode, (When Continuous Mode, receive data continuous data from BATA LASERMIKE Diameter. (use 'CONT' read command) )

I - Disable Continuous mode.

 (Refer to BETA LASERMIKE Diameter Instruction Handbook )

5) EXTRA2           Don't care.

 

 

Word Write